Saturday, June 12, 2010

Siemens Servo 300A Ventilator

Buy Siemens 300A ventilator




Siemens 300A Servo Ventilator offers a wide range of ventilation modes together with an Automode function for greater treatment possibilities, shorter weaning times and increased patient comfort.

FEATURES

  • Automode for fully adaptive patient interaction
  • Neonate to adult patient range
  • Wide range of ventilation modes
  • Easy to use

Ventilation modes:

  • Controlled
  • Supported
  • Combined

Patient range:

  • Adult
  • Pediatric
  • Neonate

Classification:

  • IEC60601-1/EN60 601-1 Type B

Dimensions:

  • Patient unit: W 242 x D 370 x H 240mm
  • User interface: W 431 x D 150 x H 325mm

Weight:

  • Approx. 24kg

Method of triggering:

  • Flow and Pressure

Siemens Servo 300 Ventilator

Siemens Servo 300 Ventilator.






Product Description

Lung ventilator intended for adult, pediatric, and neonatal patients. A refurbished Siemens 300A Servo Ventilator offers a wide range of ventilation modes together with an Automode function for greater treatment possibilities, shorter weaning times and increased patient comfort.

The 300A differs from the 300 in that it offers an Automode Feature: After two consecutivepatient trigs the ventilator shifts from controlled to supported ventilationand remains in the support mode as long as the patient keeps triggering. If the patient stops breathing, the ventilator shifts back to the control mode after: Adult 12s, Pediatric 8s, Neonatal 5s.

The Siemens 300A is comprised of 2 main components:

  • Control Unit: Contains the electronic circuits necessary for control of ventilation (panel and knobs).
  • Patient Unit: Continually neasures flow and pressure with transducers.

Features:

  • Automode
  • Neonate to adult patient range
  • Wide range of ventilation modes
  • Easy to use
  • O2 air gas module filters bacteria.

Specifications:

  • Ventilation modes:
    - Controlled
    - Supported
    - Combined
  • Patient range:
    - Adult/Pediatric/Neonate
  • Classification:
    - IEC60601-1/EN60 601-1 Type B
  • Dimensions:
    - Patient unit: W 242 x D 370 x H 240mm
    - User interface: W 431 x D 150 x H 325mm
  • Weight:
    - Approx. 24kg
  • Method of triggering:
    - Flow and Pressure

Friday, June 11, 2010

Siemens Servo 900C Ventilator


Siemens 900C ventilator



SERVO VENTILATOR 900 C Intensive care

The Servo Ventilator 900C can be used in intensive care and patient transportation, for adults, infants and pediatric patients.

SAFE and RELIABLE

  • Volume Control - set values are delivered

  • Pressure Control - efficient ventilation with low pressure

  • Keep lungs open with Pressure Control and Inverse I:E ratio

  • Pressure Support - a standard mode for weaning

  • Ventilate the lungs independently

Volume Control - set values are delivered

In Volume Controlled Ventilation the inspiratory flow is kept constant as preset by the Servo Control System. As a result the tidal volume is also delivered as preset, and inspiratory time and pause time are maintained as preset.

Pressure Control - efficient ventilation with low pressure

Pressure Control is a unique mode of the Servo Ventilator. By maintaining preset airway pressure constant throughout the entire inspiratory period, the Servo Ventilator delivers the tidal volume using a lower pressure level than traditional controlled ventilation.

Pressure Control ventilation with a constant inspiratory pressure gives you a decelerating flow with the major part of the tidal volume delivered in the beginning of the inspiration and thus prolonged time for gas exchange in the alveoli.

Keep lungs open with Pressure Control and Inverse I:E ratio

Pressure Controlled Ventilation together with Inverse I:E ratio is used to improve gas exchange and to prevent alveoli from collapsing during expiration. Using the inspiration time and pause time controls, the I:E ratio can be set from 1:4 to 4:1.

In all modes of ventilation you can easily measure intrinsic PEEP during ventilation in progress, using the Airway Pressure meter while pressing the Expiratory Pause Hold button. In this way you have control over your patient’s end expiratory lung pressure.

This means that even the most peripheral lung regions can be opened and kept open, improving ventilation distribution and at the same time reducing the risk of barotrauma.

Pressure Support - a standard mode for weaning

In 1981 the Servo Ventilator 900C was the first ventilator to introduce Pressure Support Ventilation. Since then, it has become a standard in the support and weaning of patients. Pressure Support is a spontaneous mode, where the patient controls tidal volume, frequency and inspiratory time while the Servo Control System maintains the pressure support level.

Ventilate the lungs independently

In the case of unilateral lung pathology, or uneven bilateral lung disease, ventilating the lungs differently can give considerable advantages.

Two Servo Ventilators can easily be synchronized to provide Independent Lung Ventilation (ILV). By setting the parameters independently on the two ventilators, each lung is ventilated independently of the other.

The brain of the Servo Ventilator 900C is the unique Servo Control System. Even if the resistance and compliance in the patient’s lungs and airways change, set parameters are maintained as preset.

Sensors in the patient gas delivery circuit give information back to the servo-controlled valves. Even the smallest deviations from the set values are sensed, fed back to the servo controlled valves and compensated for.

Pressure and flow are continuously measured, compared and regulated - several hundred times a second. Thus the Servo Feedback Control System gives the patient exactly the ventilation that you have chosen.